BODY CONTROL SYSTEM (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)
DTC B1010 BODY CONTROL SYSTEM (BIU) MALFUNCTION
DTC DETECTING CONDITION:
System error in body integrated unit
TROUBLE SYMPTOM:
LAN communication immobilizer function may not be executed normally.
STEP | CHECK | YES | NO |
1.CHECK DTC.
Check DTC indicated by body integrated unit. Read Diagnostic Trouble Code (DTC)">
Is B1010 current malfunction?
Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC B1010 BODY CONTROL SYSTEM (BIU) MALFUNCTION">Go to Step 2.
Temporary EEPROM access error occurred.
2.CHECK CONNECTOR.
1) Turn the ignition switch to OFF.
2) Disconnect the body integrated unit connector.
3) Connect the disconnected connectors.
4) Read the DTC of body integrated unit using Subaru Select Monitor. Read Diagnostic Trouble Code (DTC)">
Is B1010 current malfunction?
Replace the body integrated unit. Body Integrated Unit">
Temporary EEPROM access error occurred.
Welcome lighting function (if
equipped)
The welcome lighting function turns on the
low beam headlight for smooth approaching
to or exiting from the vehicle at night or
in a dark place.
The function is activated while all of the
following conditions are met.
The light control switch is in the
"AUTO" position
It is dark enoug ...
Preparation tool
CRUISE CONTROL SYSTEM (DIAGNOSTICS) > General DescriptionPREPARATION TOOL1. SPECIAL TOOLILLUSTRATIONTOOL NUMBERDESCRIPTIONREMARKS — SUBARU SELECT MONITOR 4Used for setting of each function and troubleshooting for electrical system.NOTE:For detailed operation procedures of Subaru Select Monitor ...
Dtc b2223 gerda malfunction
INSTRUMENTATION/DRIVER INFO (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B2223 GERDA MALFUNCTIONDTC DETECTING CONDITION:When the system microcomputer can not send/receive the data with the image microcomputer normally.TROUBLE SYMPTOM:There is no display on the TFT. O ...