HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Evaporator Sensor
REMOVAL
CAUTION:
Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION">
1. Using the refrigerant recovery system, discharge refrigerant. Refrigerant Recovery Procedure > PROCEDURE">
2. Disconnect the ground cable from battery and wait for at least 60 seconds before starting work. NOTE">
3. Remove the evaporator assembly - cooling. Evaporator > REMOVAL">
4. Remove the thermostat - cooling from the evaporator assembly - cooling.

Inspection
InstallationDtc p0974 shift solenoid "a" control circuit high
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P0974 SHIFT SOLENOID "A" CONTROL CIRCUIT HIGHDTC detecting condition:Immediately at fault recognitionTrouble symptom:Gear is not changed. (No up-shift)CAUTION:Use the check boar ...
Dtc b16f5 side airbag sensor lh recognition error
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B16F5 SIDE AIRBAG SENSOR LH RECOGNITION ERRORDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Side airbag sensor LH is misinstalled.• Airbag CM is faulty.CAUTION:Before performing d ...
Temperature control
Type A
Turn the temperature control dial over a
range from the blue side (cool) to red side
(warm) to regulate the temperature of
airflow from the air outlets.
Type B, C and D
Turn the temperature control dial to set the
preferred interior temperature. With the
dial set to your preferred tem ...