HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient Sensor
INSPECTION
1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.
2. Check the resistance between ambient sensor terminals.
CAUTION:
During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.
Preparation tool:
Circuit tester

Terminal No. | Inspection conditions | Standard |
1 — 2 | 10°C | 5.82 — 6.18 k? |
15°C | 4.58 — 4.87 k? | |
20°C | 3.64 — 3.86 k? | |
25°C | 2.91 — 3.09 k? | |
30°C | 2.35 — 2.49 k? | |
35°C | 1.9 — 2.02 k? | |
40°C | 1.56 — 1.65 k? | |
45°C | 1.28 — 1.36 k? | |
50°C | 1.06 — 1.12 k? | |
55°C | 0.88 — 0.93 k? | |
60°C | 0.74 — 0.78 k? |
3. Replace the ambient sensor if the inspection result is not within the standard value.
Ambient sensor
RemovalBasic diagnostic procedure Procedure
AUTO HEADLIGHT BEAM LEVELER SYSTEM (DIAGNOSTICS) > Basic Diagnostic ProcedurePROCEDURESTEPCHECKYESNO1.PERFORM CUSTOMER INTERVIEW.Using the Check List for Interview, ask the customer the condition of how the trouble occurred. Check List for Interview > CHECK">Did you interview the cust ...
Disassembly
MANUAL TRANSMISSION AND DIFFERENTIAL(5MT) > Drive Pinion Shaft AssemblyDISASSEMBLYNOTE:Attach a cloth to the end of driven shaft (on the frictional side of the thrust needle bearing) to prevent damage during disassembly or reassembly.1. Flatten the tab of the lock nut. Remove the lock nut with ST ...
Dtc p0071 ambient air temperature sensor circuit "a" range/performance
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P0071 AMBIENT AIR TEMPERATURE SENSOR CIRCUIT "A" RANGE/PERFORMANCEDTC detecting condition:Detected when two consecutive driving cycles with fault occur.CAUTION:After servicing or replacing faulty par ...