Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Inspection

HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient Sensor

INSPECTION

1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.

2. Check the resistance between ambient sensor terminals.

CAUTION:

During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.

Preparation tool:

Circuit tester

Terminal No.

Inspection conditions

Standard

1 — 2

10°C

5.82 — 6.18 k?

15°C

4.58 — 4.87 k?

20°C

3.64 — 3.86 k?

25°C

2.91 — 3.09 k?

30°C

2.35 — 2.49 k?

35°C

1.9 — 2.02 k?

40°C

1.56 — 1.65 k?

45°C

1.28 — 1.36 k?

50°C

1.06 — 1.12 k?

55°C

0.88 — 0.93 k?

60°C

0.74 — 0.78 k?

3. Replace the ambient sensor if the inspection result is not within the standard value.

Ambient sensor
...

Removal
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient SensorREMOVAL1. Disconnect the ground cable from battery. Battery > REMOVAL">2. Remove the ambient sensor.(1) Disconnect the connector ...

Other materials:

Disassembly
MANUAL TRANSMISSION AND DIFFERENTIAL(5MT) > Transfer Driven GearDISASSEMBLY1. Using the ST, remove the taper roller bearing (extension case side).ST 498077000REMOVER(A)Taper roller bearing (extension case side)2. Using ST1 and ST2, remove the taper roller bearing (transfer case side).ST1 49 ...

Cooling system Inspection
PERIODIC MAINTENANCE SERVICES > Cooling SystemINSPECTION1. RADIATORCheck that there are no engine coolant leaks from the hose connections. Refer to “CO” section for radiator inspection. Radiator > INSPECTION">2. RADIATOR CAPRefer to “CO” section for radiator ca ...

Operation
Blind Spot Detection/Rear Cross Traffic Alert (DIAGNOSTICS) > Subaru Select MonitorOPERATION• For detailed operation procedures, refer to “Application help”.• When the radar sensor cannot communicate with Subaru Select Monitor, perform “COMMUNICATION FOR INITIALIZING ...

© 2016-2024 Copyright www.sucross.com