EyeSight > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and inspect visually.
2. If the fuse is blown out, replace the fuse.
NOTE:
If the fuse is blown again, check the system wiring harness.
2. CHECK RELAY
1. Measure the resistance between relay terminals.
Terminal No. | Inspection conditions | Standard | Circuit |
1 — 2 | Always | 1 M? or more |
1 — 4
Always
Less than 1 ?
1 — 2
Apply battery voltage between terminals 3 and 5.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Outside temperature indicator
U.S.-spec. models
Except U.S.-spec. models
The outside temperature indicator shows
the outside temperature in a range from
−40 to 1228F (−40 to 508C).
The indicator can give a false reading
under any of the following conditions.
When there is too much sun.
During ...
Dtc c1331 rr hold valve
VEHICLE DYNAMICS CONTROL (VDC) (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC C1331 RR HOLD VALVENOTE:For the diagnostic procedure, refer to “DTC C1362 NORMAL CLOSING VALVE 2”. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC C1362 NORMAL C ...
Front passenger's SRS frontal airbag
The front passenger's SRS frontal airbag
uses a dual stage inflator. The inflator
operates in different ways depending on
the severity of impact.
The occupant detection system sensor is
installed under the seat upholstery and
monitors the physique and posture of the
front passenger. Using t ...