IMMOBILIZER (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)
DTC B1408 METER NON-VOLATILE MEMORY
DTC DETECTING CONDITION:
Defective combination meter
CAUTION:
When the combination meter is replaced, registration of the immobilizer system is required. For details, refer to the “REGISTRATION MANUAL FOR IMMOBILIZER” provided as a separate volume.
| STEP | CHECK | YES | NO |
1.CHECK COMBINATION METER REGISTRATION.
1) Perform the Clear Memory Mode. (Combination meter Clear Memory Mode">
and body integrated unit Clear Memory Mode">
)
2) Perform registration of combination meter. Refer to the “REGISTRATION MANUAL FOR IMMOBILIZER” provided as a separate volume.
3) Perform the Clear Memory Mode. Clear Memory Mode">
4) Read the DTC of the body integrated unit. Read Diagnostic Trouble Code (DTC)">
Is DTC B1408 detected?
Replace the combination meter. Combination Meter">
Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
Dtc b1407 met communication
Dtc b1409 scu communicationLocation
ENTERTAINMENT > General DescriptionLOCATION1. AUDIO AND NAVIGATION SYSTEM(1)Telematics sub antenna(3)Speaker ASSY - tweeter front LH(5)Data communication module(2)GPS antenna ASSY(4)Audio ASSY or navigation ASSY(6)Speaker ASSY - tweeter front RH*1: Model with telematics(1)Telematics antenna(4)Fro ...
Assembly
REAR SUSPENSION > Front Lateral LinkASSEMBLY1. Before assembly, inspect the following items and replace any faulty part with a new one.• Visually check the lateral link assembly - front for damage and deformation.• Visually check the bushing for abnormal cracks, fatigue or damage.&bul ...
Inspection
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Fuel Sub Level SensorINSPECTION1. Check that the fuel sub level sensor has no damage.2. Measure the fuel sub level sensor float position.(1)FULL(2)EMPTY(3)Datum pointsFloat positionStandardFULL to Datum point (A)5.31±3.5 mm (0.209±0.138 in)EMPTY to Datum po ...