HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Refrigerant Pressure with Manifold Gauge Set
INSPECTION
1. INSPECTION WITH PRESSURE SYMPTOMS
Symptoms | Reference |
Both high and low pressure sides are low. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
Both high and low pressure sides are high. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
Both high and low pressure sides are equal, or high-pressure side is low. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
High-pressure side is high. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
Low-pressure side is low. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
Low-pressure side is high. | Refrigerant Pressure with Manifold Gauge Set > INSPECTION"> |
2. BOTH HIGH AND LOW PRESSURE SIDES ARE LOW
| STEP | CHECK | YES | NO |
1.CHECK REFRIGERANT LEAKAGE.
Check the refrigerant for leakage. Refrigerant Leak Check > INSPECTION">
NOTE:
When the pressure on the high-pressure side is less than 0.69 Mpa: Go to Step 2.
Are there any refrigerant leakage?
Repair the refrigerant leakage.
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 2.
2.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Perform appropriate inspection with pressure symptoms.
3. BOTH HIGH AND LOW PRESSURE SIDES ARE HIGH
| STEP | CHECK | YES | NO |
1.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Perform appropriate inspection with pressure symptoms.
4. BOTH HIGH AND LOW PRESSURE SIDES ARE EQUAL, OR HIGH-PRESSURE SIDE IS LOW
| STEP | CHECK | YES | NO |
1.CHECK REFRIGERANT LEAKAGE.
Check the refrigerant for leakage. Refrigerant Leak Check > INSPECTION">
NOTE:
When the pressure on the high-pressure side is less than 0.69 Mpa: Go to Step 2.
Are there any refrigerant leakage?
Repair the refrigerant leakage.
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 2.
2.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Inspect the compressor. Diagnostics with Phenomenon > DIAGNOSTIC PROCEDURE WITH PHENOMENON">
5. HIGH-PRESSURE SIDE IS HIGH
| STEP | CHECK | YES | NO |
1.CHECK CONDENSER.
Check the condenser. Condenser > INSPECTION">
Is condenser normal?
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 2.
Clean or replace the condenser.
2.CHECK RADIATOR FAN.
Check the radiator fan system. Radiator Fan System">
Is radiator fan system normal?
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 3.
Repair or replace the faulty parts of the radiator fan system.
3.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Check the high-pressure hose and condenser for deformation or clogging, and replace if defective.
6. LOW-PRESSURE SIDE IS LOW
| STEP | CHECK | YES | NO |
1.CHECK REFRIGERANT LEAKAGE.
Check the refrigerant for leakage. Refrigerant Leak Check > INSPECTION">
NOTE:
When the pressure on the high-pressure side is less than 0.69 Mpa: Go to Step 2.
Are there any refrigerant leakage?
Repair the refrigerant leakage.
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 2.
2.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 3.
3.REPLACE EXPANSION VALVE.
Replace the expansion valve. Expansion Valve > REMOVAL">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Inspect the compressor. Diagnostics with Phenomenon > DIAGNOSTIC PROCEDURE WITH PHENOMENON">
7. LOW-PRESSURE SIDE IS HIGH
| STEP | CHECK | YES | NO |
1.FILL PROPER AMOUNT OF REFRIGERANT.
Drain the refrigerant completely, and then refill the proper amount of refrigerant.
• Recovery: Refrigerant Recovery Procedure > PROCEDURE">
• Refill: Refrigerant Charging Procedure > PROCEDURE">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Refrigerant Pressure with Manifold Gauge Set > INSPECTION">Go to Step 2.
2.REPLACE EXPANSION VALVE.
Replace the expansion valve. Expansion Valve > REMOVAL">
Is the refrigerant pressure within the specified range?
Refrigerant pressure is normal.
Replace the evaporator. Evaporator > REMOVAL">
ProcedureSteps for Determining Correct Load Limit
1. Locate the statement "The combined
weight of occupants and
cargo should never exceed XXX
kg or XXX lbs." on your vehicle's
placard.
2. Determine the combined weight
of the driver and passengers that
will be riding in your vehicle.
3. Subtract the combined weight of
the driver and pas ...
Removal
EXTERIOR/INTERIOR TRIM > Roof SpoilerREMOVAL1. Disconnect the ground cable from battery. NOTE">2. Remove the trim panel - rear gate UPR. Rear Gate Trim > REMOVAL">3. Remove the roof spoiler assembly.(1) Disconnect the connector of high-mounted stop light.(2) Remove the caps, ...
List of cancel code List
CRUISE CONTROL SYSTEM (DIAGNOSTICS) > List of Cancel CodeLISTNOTE:• The cancel code is registered even when cancel is performed intentionally by the driver.• Cancel codes are cleared if the ignition switch is turned to OFF.• If a different cancel code is input after a cancel cod ...