Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Dtc b1828 short in side airbag lh (to +b)

AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble Code

DTC B1828 SHORT IN SIDE AIRBAG LH (TO +B)

Diagnosis start condition:

Ignition voltage is 10 V to 16 V.

DTC detecting condition:

Side airbag harness (LH) is shorted to power supply.

Side airbag module (LH) is faulty.

Airbag control module is faulty.

CAUTION:

Before performing diagnosis, refer to “CAUTION” in “General Description”. General Description > CAUTION">

Wiring diagram:

Airbag system Airbag System > WIRING DIAGRAM">

STEPCHECKYESNO

1.CHECK POOR CONTACT OF CONNECTORS.

Check for poor contact of the connectors between the airbag control module, side airbag module LH and the side airbag sensor LH.

Is there poor contact?

Replace the airbag rear harness along with body harness.

Diagnostic Chart with Trouble Code > DTC B1828 SHORT IN SIDE AIRBAG LH (TO +B)">Go to Step 2.

2.CHECK SIDE AIRBAG MODULE.

1) Turn the ignition switch to OFF, disconnect the battery ground cable, and wait for 60 seconds or more.

2) Disconnect the connector (AB19), and connect the connector (1AJ) in test harness AJ to connector (AB19).

3) Connect the airbag resistor to the test harness AJ connector (3AJ).

4) Connect the battery ground terminal and turn the ignition switch to ON.

Does the airbag warning light illuminate for six seconds and go off?

Replace the side airbag module (LH). Side Airbag Module > REMOVAL">

Diagnostic Chart with Trouble Code > DTC B1828 SHORT IN SIDE AIRBAG LH (TO +B)">Go to Step 3.

3.CHECK AIRBAG REAR HARNESS (SIDE AIRBAG MODULE HARNESS LH).

1) Turn the ignition switch to OFF, disconnect the battery ground cable, and wait for 60 seconds or more.

2) Disconnect the connector (AB21) from seat belt pretensioner (LH).

3) Disconnect the connector (AB31) from curtain airbag module (LH).

4) Disconnect the airbag resistor from test harness.

5) Disconnect the connectors (AB6, AB17, AB18) from airbag control module.

6) Connect the connector (1AG) in the test harness AG to the connectors (AB6, AB17, AB18).

7) Connect the battery ground terminal and turn the ignition switch to ON.

8) Measure the voltage between connector (5AG) in the test harness AG and chassis ground.

Connector & terminal

(5AG) No. 1 (+) — Chassis ground (−):

(5AG) No. 3 (+) — Chassis ground (−):

Is the voltage less than 1 V?

Diagnostic Chart with Trouble Code > DTC B1828 SHORT IN SIDE AIRBAG LH (TO +B)">Go to Step 4.

Replace the airbag rear harness along with body harness.

4.CHECK AIRBAG CONTROL MODULE.

1) Connect all connectors.

2) Clear the memory. Clear Memory Mode">

3) Perform the Inspection Mode. Inspection Mode">

4) Read the DTC. (Current malfunction) Read Diagnostic Trouble Code (DTC)">

Is DTC B1828 displayed?

Replace the airbag control module. Airbag Control Module">

Diagnostic Chart with Trouble Code > DTC B1828 SHORT IN SIDE AIRBAG LH (TO +B)">Go to Step 5.

5.CHECK FOR ANY OTHER DTC ON DISPLAY.

Is any other DTC displayed?

Check DTC using “List of Diagnostic Trouble Code (DTC)”. List of Diagnostic Trouble Code (DTC)">

Finish the diagnosis.

Dtc b1827 short in side airbag lh (to ground)
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1827 SHORT IN SIDE AIRBAG LH (TO GROUND)Diagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:&bull ...

Dtc b1830 short in curtain airbag rh squib circuit
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1830 SHORT IN CURTAIN AIRBAG RH SQUIB CIRCUITDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition: ...

Other materials:

Installation
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Drive Pinion Shaft AssemblyINSTALLATION1. Clean the mating surface of drive pinion retainer and converter case.2. Adjust the backlash and tooth contact between drive pinion shaft assembly and the front differential side gear. Drive Pinion Shaft Assembl ...

Dtc b1903 short in front p/t rh (to +b)
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1903 SHORT IN FRONT P/T RH (TO +B)Diagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Seat belt pretensioner (RH) circuit is shorted to power supply.• Pretensioner (RH) is faulty.&bul ...

Wiring diagram
INSTRUMENTATION/DRIVER INFO > Combination Meter SystemWIRING DIAGRAMRefer to “Combination Meter System” in the wiring diagram.– Models with normal meters: Combination Meter System > WIRING DIAGRAM">– Model with color TFT meter: Combination Meter System > WIRING D ...

© 2016-2024 Copyright www.sucross.com