CAUTION
Do not operate the starter motor continuously for more than 10 seconds.
If the engine fails to start after operating the starter for 5 to 10 seconds, wait for 10 seconds or more before trying again.
NOTE
It may be difficult to start the engine when the battery has been disconnected and reconnected (for maintenance or other purposes). This difficulty is caused by the electronically controlled throttle's self-diagnosis function. To overcome it, keep the ignition switch in the "ON" position for approximately 10 seconds before starting the engine.
General precautions when starting/stopping engine
MT modelsDtc p000b "b" camshaft position slow response bank 1
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P000B "B" CAMSHAFT POSITION SLOW RESPONSE BANK 1NOTE:For the diagnostic procedure, refer to DTC P0014. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P0014 "B" CAMSHAFT P ...
Preparation tool
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > General DescriptionPREPARATION TOOL1. SPECIAL TOOLILLUSTRATIONTOOL NUMBERDESCRIPTIONREMARKS18471AA000FUEL PIPE ADAPTERUsed for draining fuel. — SUBARU SELECT MONITOR 4Used for setting of each function and troubleshooting for electrical system.NOTE:For detai ...
Disassembly
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Front Differential AssemblyDISASSEMBLY1. DIFFERENTIAL CASE ASSEMBLY1. Remove the taper roller bearing using the ST.ST1 498077000REMOVERST2 899864100REMOVERST3 398497701SEAT2. Remove the hypoid driven gear mounting bolt using the ST.ST 18270K ...