HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Mode Door Actuator
INSPECTION
1. CHECK LINK
1. Visually check the operation range of the link, and remove the foreign material if any.
2. Operate the air flow control dial or switch to check that the link operates normally.
3. If it does not operate normally as the result of inspection, check the motor - actuator mode.
2. CHECK ACTUATOR
1. Check the resistance between actuator terminals.
Preparation tool:
Circuit tester
Terminal No. | Inspection conditions | Standard | Connector Sketch |
3 — 1 | Always | 80 — 100 ? |

3 — 2
3 — 5
3 — 6
2. Replace the motor - actuator mode if it is found defective as a result of inspection.
RemovalRemoval
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Fuel Level SensorREMOVALWARNING:Place “NO OPEN FLAMES” signs near the working area.CAUTION:• Be careful not to spill fuel.• If the fuel gauge indicates that two thirds or more of the fuel is remaining, be sure to drain fuel before star ...
Dtc p0961 pressure control solenoid "a" control circuit range/performance
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P0961 PRESSURE CONTROL SOLENOID "A" CONTROL CIRCUIT RANGE/PERFORMANCEDTC DETECTING CONDITION:Immediately at fault recognitionTROUBLE SYMPTOM:• Acceleration is poor during ...
List
TELEMATICS SYSTEM (DIAGNOSTICS) > System Operation Check ModeLISTSystem operation check modeNoteGREEN LED LightingGREEN LED illuminates/flashes/goes off.GREEN LED FlashingGREEN LED OFFRED LED LightingRED LED illuminates/flashes/goes off.RED LED FlashingRED LED OFFSpeaker ONOutputs to speaker. ...