CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)
DTC U0422 INVALID DATA RECEIVED FROM BODY CONTROL MODULE
NOTE:
Refer to “LAN SYSTEM (DIAGNOSTICS)” for diagnostic procedures. Basic Diagnostic Procedure">
1. OUTLINE OF DIAGNOSIS
• Detect malfunction of CAN communication.
• Judge as NG when data received from the body integrated unit is not normal.
2. EXECUTION CONDITION
Secondary parameters | Execution condition |
12 V battery system voltage | ≥ 10 V |
Measured turbine shaft speed | > 0 rpm |
or | |
Transmission range | Drive or Reverse |
3. DIAGNOSTIC METHOD
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Malfunction Criteria | Threshold Value |
CAN data from BIU | Freeze |
Time Needed for Diagnosis: 2 seconds
Malfunction Indicator Light Illumination: Does not illuminate.
Dtc u0416 invalid data received from vehicle dynamics control module
Dtc u0423 invalid data received from instrument panel cluster control moduleFront passenger's SRS frontal airbag
The front passenger's SRS frontal airbag
uses a dual stage inflator. The inflator
operates in different ways depending on
the severity of impact.
The occupant detection system sensor is
installed under the seat upholstery and
monitors the physique and posture of the
front passenger. Using t ...
Parking brake stroke
Check the parking brake stroke according
to the maintenance schedule in the
"Warranty and Maintenance Booklet".
When the parking brake is properly
adjusted, braking power is fully applied
by pulling the lever up 7 to 8 notches
gently but firmly (approximately 45 lbf [200
N, 20.4 kgf]). ...
Dtc b1830 short in curtain airbag rh squib circuit
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1830 SHORT IN CURTAIN AIRBAG RH SQUIB CIRCUITDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Curtain airbag harness (RH) circuit is shorted.• Curtain airbag module (RH) is faulty. ...