CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)
DTC U0401 INVALID DATA RECEIVED FROM ECM/PCM “A”
NOTE:
Refer to “LAN SYSTEM (DIAGNOSTICS)” for diagnostic procedures. Basic Diagnostic Procedure">
1. OUTLINE OF DIAGNOSIS
• Detect malfunction of CAN communication.
• Judge as NG when data received from ECM is not normal.
2. EXECUTION CONDITION
Secondary Parameters | Execution condition |
12 V battery system voltage | ≥ 10 V |
Measured turbine shaft speed | > 0 rpm |
or | |
Transmission range | Drive or Reverse |
3. DIAGNOSTIC METHOD
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Malfunction Criteria | Threshold Value |
CAN data from ECM | Did not change |
Time Needed for Diagnosis: 2 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Dtc u0164 lost communication with hvac control module
Dtc u0416 invalid data received from vehicle dynamics control moduleBasic diagnostic procedure Procedure
TELEMATICS SYSTEM (DIAGNOSTICS) > Basic Diagnostic ProcedurePROCEDURESTEPCHECKYESNO1.PERFORM CUSTOMER INTERVIEW.Using the Check List for Interview, ask the customer the condition of how the trouble occurred. Check List for Interview > CHECK">Did you interview the customer? Basic Diagn ...
Inspection
SUNROOF/T-TOP/CONVERTIBLE TOP (SUNROOF) > Sunroof SwitchINSPECTION1. Check the resistance between connector terminals.Preparation tool:Circuit testerTerminal No.Inspection conditionsStandardConnector1 — 3OpenLess than 1 ?(b): Slide switch4 — 3CloseLess than 1 ?1 — 3Tilt upLess than 1 ?(a): ...
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > FRESH/RECIRC Door ActuatorINSPECTION1. CHECK LINK1. Visually check the operation range of the link, and remove the foreign material if any.2. Operate the FRESH/RECIRC switch to check that the link operates normally.3. If it does not operate normally as t ...