SECURITY AND LOCKS > IG Relay1 (Push Button Start)
REMOVAL
CAUTION:
Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION">
1. Disconnect the ground cable from battery and wait for at least 60 seconds before starting work. NOTE">
2. Remove the cover assembly - instrument panel LWR driver. Instrument Panel Lower Cover > REMOVAL">
3. Remove the knee airbag module. Knee Airbag Module > REMOVAL">
4. Release the lock and remove the fuse holder.
5. Remove the relay & fuse box.
(1) Disconnect the connector.
(2) Remove the bolts and nuts, and remove the relay & fuse box.
6. Remove IG relay 1 (push button start) (A) from the relay holder.
Inspection
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Knock SensorINSPECTION1. Check that the knock sensor has no deformation, cracks or other damages.2. Measure the resistance between knock sensor terminals.Terminal No.Standard1 and 2560±28 k? ...
Inspection
LIGHTING SYSTEM > Rear Combination Light AssemblyINSPECTION1. Apply battery voltage between the connector terminals to check the lighting condition of the light.Terminal No.Inspection conditionsSpecification6 (+) — 3 (−)Apply battery voltage.Stop light on2 (+) — 3 (−)Tail (small) ...
Installation
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Front Oxygen (A/F) SensorINSTALLATIONCAUTION:If lubricant is spilt over the exhaust pipe, wipe it off with cloth to avoid emission of smoke or causing a fire.1. Before installing front oxygen (A/F) sensor, apply anti-seize compound only to the threaded portio ...