CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Oil Pump
REMOVAL
1. Remove the transmission assembly from the vehicle. Automatic Transmission Assembly > REMOVAL">
2. Remove the torque converter assembly. Torque Converter Assembly > REMOVAL">
3. Remove the oil pump chain cover. Oil Pump Chain > REMOVAL">
4. Remove the oil pump and the plate.

5. Remove the O-ring.

Inspection
InstallationAdjustment
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Differential Gear OilADJUSTMENTNOTE:Immediately after removing the overflow drain plug, remaining gear oil (approx. 8 cc) may come out of the overflow pipe. This is not included in the specified amount. When removing the overflow drain plug, make sure t ...
Inspection
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Control PanelINSPECTION1. CHECK ILLUMINATION1. Check the illumination operation when battery voltage is applied between the terminals of control panel.• Manual A/C modelTerminal No.Inspection conditionsSpecificationConnection diagram14 (+) — 12 ( ...
Inspection
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Mass Air Flow and Intake Air Temperature SensorINSPECTION1. CHECK THE MASS AIR FLOW SENSOR UNIT1. Connect the battery positive terminal to terminal No. 3 and the battery ground terminal to terminal No. 4, the circuit tester positive terminal to terminal No. 5 ...