HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > General Description
PREPARATION TOOL
1. SPECIAL TOOL
ILLUSTRATION | TOOL NUMBER | DESCRIPTION | REMARKS |
—
SUBARU SELECT MONITOR 4
Used for setting of each function and troubleshooting for electrical system.
NOTE:
For detailed operation procedures of Subaru Select Monitor 4, refer to “Application help”.
2. GENERAL TOOL
CAUTION:
When working on vehicles with a HFC-134a system, only use HFC-134a specified tools and parts. Do not mix CFC-12 tools and parts. If HFC-134a and CFC-12 compressor oil is mixed, it will result in poor lubrication and the compressor itself may be damaged.
In order to prevent the mixture of HFC-134a and CFC-12 parts and liquid, the type of tool and screw, and the replacement valves used are different. The gas leak detectors for the HFC-134a and CFC-12 systems must also not be interchanged.
HFC-134a | CFC-12 | |
Tool and screw type | Millimeter size | Inch size |
Valve type | Quick joint type | Screw-in type |
TOOL NAME/ILLUSTRATION | REMARKS |
Circuit tester | Used for measuring resistance, voltage and current. |
DST-i | Used together with Subaru Select Monitor 4. |
Wrench | Various WRENCHES will be required to service any A/C system.7 — 40 N·m (0.7 to 4.1 kgf-m, 5 to 30 ft-lb) torque wrench and various crowfoot wrenches will be needed. Open end or flare nut wrenches will be needed to affix the pipe and hose fittings. |
Applicator bottle
A small APPLICATOR BOTTLE is recommended to apply compressor oil to the various parts. It can be available at a hardware store.
Manifold gauge set
A MANIFOLD GAUGE SET (with hoses) is available at either a refrigerant supplier or an automotive equipment supplier.
Refrigerant recovery system
A REFRIGERANT RECOVERY SYSTEM is used for the recovery and recycling of A/C system refrigerant after contaminants and moisture have been removed from the refrigerant.
Syringe
A graduated plastic SYRINGE will be needed to add oil into the system again. A syringe can be available at a pharmacy or drug store.
Vacuum pump
A VACUUM PUMP is necessary (for a good working condition), and may be available at either a refrigerant supplier or an automotive equipment supplier.
Can tap
A CAN TAP for the 397 g (14 oz) can is available at an automotive equipment supplier.
Thermometer/hygrometer
A Pocket THERMOMETER/HYGROMETER is available at either a industrial hardware store or a refrigerant supplier.
Electronic leak detector
An ELECTRONIC LEAK DETECTOR can be available at either a specialty tool supplier or an A/C equipment supplier.
Weight scale
A WEIGHT SCALE such as an electronic charging scale or a bathroom scale with digital display will be needed, if a 13.6 kg (30 lb) refrigerant container is used.
Installation
MECHANICAL(H4DO) > V-beltINSTALLATION1. V-BELTInstall in the reverse order of removal.CAUTION:• When reusing the V-belt, wipe off dust and water with cloth.• Do not use the V-belt if there is any oil, grease or coolant on the belt.• Be careful not to rub the V-belt end surface w ...
Inspection
MANUAL TRANSMISSION AND DIFFERENTIAL(5MT) > Main Shaft AssemblyINSPECTIONDisassembled parts should be washed with cleaning solvent first, then inspected carefully.1. BearingReplace the bearings in the following cases.• When the bearing balls, outer races and inner races are broken or rusty. ...
15
CRUISE CONTROL SYSTEM (DIAGNOSTICS) > Diagnostic Procedure with Cancel Code15Detected when CANCEL switch is pressed or malfunction related to CRUISE switch occurs.TROUBLE SYMPTOM:• Cruise control cannot be set. (Cancelled immediately.)• Cruise control cannot be released.Refer to DTC 1 ...