Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Inspection

STARTING/CHARGING SYSTEMS(H4DO) > Generator

INSPECTION

1. DIODE

CAUTION:

There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.

1. Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.

At analog type tester

Tester lead

Continuity

−lead

+lead

E

P1, P2, P3, P4, P5, P6

Yes

B

No

P1, P2, P3, P4, P5, P6

E

No

B

Yes

At digital type tester

Tester lead

Continuity

−lead

+lead

E

P1, P2, P3, P4, P5, P6

No

B

Yes

P1, P2, P3, P4, P5, P6

E

Yes

B

No

2. ROTOR

1. Slip ring surface

Inspect the slip rings for contamination or any roughness on the sliding surface. Repair the slip ring surface using a lathe or sand paper.

2. Slip ring outer diameter

Measure the slip ring outer diameter. Replace the rotor if the slip ring is worn.

Slip ring outer diameter:

Standard

22.7 mm (0.894 in)

Limit

22.1 mm (0.870 in)

3. Continuity test

Using a circuit tester, check the resistance between slip rings. If the resistance is not within the standard, replace the rotor.

Standard:

Approx. 2.0 — 2.4 ?

4. Insulation test

Check the continuity between slip ring and rotor core or shaft. If there is continuity, replace the rotor because the rotor coil is grounded.

5. Bearing

Check the bearings. If there is any noise, or the rotor does not rotate smoothly, replace the bearings.

3. STATOR COIL

1. Continuity test

Inspect the continuity between the stator coil terminals. If continuity is not as shown in the table, replace the stator coil.

(A)

Terminals

2. Insulation test

Inspect the continuity between the stator coil stator core and lead wire terminals. If there is continuity, replace the stator coil because the stator coil is grounded.

4. BRUSH

1. Measure the length of each brush. Replace the brush if wear exceeds service limits. There is a service limit mark (A) on each brush.

Brush length:

Standard (1)

22.5 mm (0.886 in)

Limit (2)

5.0 mm (0.197 in)

2. Check that there is appropriate pressure on the brush spring. Using a spring pressure indicator, push the brush into the brush holder until its tip protrudes 2 mm (0.0787 in). Then measure the pressure of brush spring. If the pressure is 1.7 N (173 gf, 6.11 ozf) or less, replace the brush spring. 4.1 — 5.3 N (418 — 540 gf, 14.75 — 19.06 ozf) pressure is required on the new spring.

5. BALL BEARING

Check the ball bearings. Replace the ball bearings if there is resistance in the rotation, or if there is any abnormal noise.

Disassembly
STARTING/CHARGING SYSTEMS(H4DO) > GeneratorDISASSEMBLY1. Remove the cap from the generator.2. Remove four bolts.3. Use a drier to heat the rear cover (A) portion to 50 — 60°C (122 — ...

Installation
STARTING/CHARGING SYSTEMS(H4DO) > GeneratorINSTALLATION1. Temporarily install the generator bracket to the engine and tighten the bolts in the numerical order.Tightening torque:36 N·m (3.7 k ...

Other materials:

Installation
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Front Differential AssemblyINSTALLATION1. Install the front differential assembly to the converter case.NOTE:Be careful not to damage the inside of the case (especially the mounting surface of the differential side retainers).2. Install the bearing oute ...

Using the voice command system
Steering switch Talk switch Action Function Press Start the voice command system. Press and hold Cancel voice recognition. Microphone Type A Type B It is unnecessary to speak directly into the microphone when giving a command. NOTE Wait ...

Assembly
COOLING(H4DO) > Radiator Main Fan and Fan MotorASSEMBLYAssemble in the reverse order of disassembly.Tightening torque:4.41 N·m (0.45 kgf-m, 3.25 ft-lb)Tightening torque:3.4 N·m (0.3 kgf-m, 2.5 ft-lb) ...

© 2016-2024 Copyright www.sucross.com