INSPECTION

Check the removed cable and replace or adjust if damaged, rusty or malfunctioning.

1. Check the cable for smooth operation.

2. Check the inner cable for damage and rust.

3. Check the outer cable for damage, bends and cracks.

4. Check the boot for damage, cracks and deterioration.

5. Move the select lever from “P” to “D” range. Check the existence of feel to contact the detents in each range. If the detents cannot be felt or the position pointer is improperly aligned, adjust the cable.

6. Check if the starter motor rotates when the select lever is set to “P” range.

7. Check the back-up light illumination when the select lever is in “R” range.

8. Check the parking lock operation when the select lever is in “P” range.

Removal
CONTROL SYSTEMS > Select CableREMOVAL1. Shift the select lever to “N” range.2. Disconnect the ground cable from battery. NOTE">NOTE:For model with battery sensor, disconnect th ...

Installation
CONTROL SYSTEMS > Select CableINSTALLATION1. Position the select cable as shown in the figure, and install it to the plate assembly.CAUTION:• If the cable is installed in the wrong direction, ...

Other materials:

Dtc b1816 open in passenger s airbag dual stage - 2nd step
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1816 OPEN IN PASSENGER’S AIRBAG DUAL STAGE - 2ND STEPDiagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Airbag main harness circuit is open.• Airbag module harness (passenger&r ...

Disassembly
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Front Differential AssemblyDISASSEMBLY1. DIFFERENTIAL CASE ASSEMBLY1. Remove the taper roller bearing using the ST.ST1 498077000REMOVERST2 899864100REMOVERST3 398497701SEAT2. Remove the hypoid driven gear mounting bolt using the ST.ST 18270K ...

Inspection
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Crankshaft Position SensorINSPECTION1. CRANKSHAFT POSITION SENSOR (METHOD WITH OSCILLOSCOPE)1. Prepare an oscilloscope.2. Remove the glove box. Glove Box > REMOVAL">3. Connect the probe to ECM connector.Terminal No.Probe16+1−4. Start the eng ...

© 2016-2026 Copyright www.sucross.com