COMMUNICATION SYSTEM > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and check visually.
2. If the fuse is blown out, replace the fuse.
2. CHECK RELAY
1. Check the resistance between relay terminals.
Terminal No. | Inspection conditions | Specification | Circuit |
1 — 2 | Always | 1 M? or more |

1 — 2
Apply battery voltage between 4 — 3 terminals.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Relay and fuse
LocationInspection
COOLING(H4DO) > ThermostatINSPECTION1. Check that the thermostat does not have deformation, cracks or damage.2. Check that the thermostat valve closes completely at an ambient temperature.3. Immerse the thermostat and a thermometer in water. Raise water temperature gradually, and check the temper ...
Dtc u0423 invalid data received from instrument panel cluster control module
EyeSight (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U0423 INVALID DATA RECEIVED FROM INSTRUMENT PANEL CLUSTER CONTROL MODULEFailure counter diagnosis of combination meterNOTE:Perform the diagnosis for LAN system. Basic Diagnostic Procedure > PROCEDURE"> ...
Canceling the function for meter/gauge needle movement upon turning on the
ignition switch
It is possible to activate or deactivate the
movement of the meter needles and
gauge needles that takes place when the
ignition switch is turned to the "ON"
position.
Type A combination meter
To change the setting, perform the following
procedure.
1. Turn the ignition switch to the "LOCK"/ ...