COMMUNICATION SYSTEM > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and check visually.
2. If the fuse is blown out, replace the fuse.
2. CHECK RELAY
1. Check the resistance between relay terminals.
Terminal No. | Inspection conditions | Specification | Circuit |
1 — 2 | Always | 1 M? or more |

1 — 2
Apply battery voltage between 4 — 3 terminals.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Relay and fuse
LocationDtc u0424 invalid data received from hvac control module
LAN SYSTEM (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U0424 INVALID DATA RECEIVED FROM HVAC CONTROL MODULEDTC DETECTING CONDITION:Defective data was transmitted from A/C control panel.TROUBLE SYMPTOM:Cooperation control of air conditioner does not operate properly. ...
Dtc b28b5 +b circuit open
EyeSight (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B28B5 +B CIRCUIT OPENDetected when there is an open circuit in power supply line.NOTE:Refer to DTC B2814 for diagnostic procedure. Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC B2814 POWER SUPP ...
Removal