COMMUNICATION SYSTEM > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and check visually.
2. If the fuse is blown out, replace the fuse.
2. CHECK RELAY
1. Check the resistance between relay terminals.
Terminal No. | Inspection conditions | Specification | Circuit |
1 — 2 | Always | 1 M? or more |

1 — 2
Apply battery voltage between 4 — 3 terminals.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Relay and fuse
LocationLocation
SECURITY AND LOCKS > Relay and FuseLOCATIONMain fuse boxFuse 15 A (key warning switch, turn signal & hazard unit, body integrated unit)(A)Fuse 20 A (body integrated unit, immobilizer antenna)(B)Relay & fuse boxFuse 15 A (body integrated unit)(C)Fuse 10 A (keyless access CM, TPMS & key ...
Dtc p0138 o2 sensor circuit high voltage bank 1 sensor 2
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P0138 O2 SENSOR CIRCUIT HIGH VOLTAGE BANK 1 SENSOR 2DTC detecting condition:Detected when two consecutive driving cycles with fault occur.CAUTION:After servicing or replacing faulty parts, perform Clear Memory ...
Dtc b1823 short in side airbag rh (to +b)
AIRBAG SYSTEM (DIAGNOSTICS) > Diagnostic Chart with Trouble CodeDTC B1823 SHORT IN SIDE AIRBAG RH (TO +B)Diagnosis start condition:Ignition voltage is 10 V to 16 V.DTC detecting condition:• Side airbag harness (RH) is shorted to power supply.• Side airbag module (RH) is faulty.• ...