COMMUNICATION SYSTEM > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and check visually.
2. If the fuse is blown out, replace the fuse.
2. CHECK RELAY
1. Check the resistance between relay terminals.
Terminal No. | Inspection conditions | Specification | Circuit |
1 — 2 | Always | 1 M? or more |

1 — 2
Apply battery voltage between 4 — 3 terminals.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Relay and fuse
LocationAssembly
DIFFERENTIALS > Rear Differential (T-type)ASSEMBLYNOTE:• Assemble in the reverse order of disassembly.• Check and adjust each part during assembly.• Keep the shims and washers in order, so that they are not improperly installed.• Thoroughly clean the surfaces on which the ...
Dtc b14e5 mode door actuator stepping motor circuit open
HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B14E5 MODE DOOR ACTUATOR STEPPING MOTOR CIRCUIT OPENDTC detecting condition:Mode door actuator stepping motor circuit is open.Trouble symptom:Vent does not change.Wiring diagram:Air conditioning syst ...
Dtc b1401 meter collation
IMMOBILIZER (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B1401 METER COLLATIONDTC DETECTING CONDITION:Reference code incompatibility between combination meter and body integrated unitCAUTION:When the combination meter is replaced, registration of the immobilizer syst ...