COMMUNICATION SYSTEM > Relay and Fuse
INSPECTION
1. CHECK FUSE
1. Remove the fuse and check visually.
2. If the fuse is blown out, replace the fuse.
2. CHECK RELAY
1. Check the resistance between relay terminals.
Terminal No. | Inspection conditions | Specification | Circuit |
1 — 2 | Always | 1 M? or more |

1 — 2
Apply battery voltage between 4 — 3 terminals.
Less than 1 ?
2. Replace the relay if the inspection result is not within the standard value.
Relay and fuse
LocationAdjustment
CONTINUOUSLY VARIABLE TRANSMISSION(TR580) > Differential Gear OilADJUSTMENTNOTE:Immediately after removing the overflow drain plug, remaining gear oil (approx. 8 cc) may come out of the overflow pipe. This is not included in the specified amount. When removing the overflow drain plug, make sure t ...
Installation
SECURITY AND LOCKS > Accessory Relay (Push Button Start)INSTALLATIONCAUTION:Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION">Install each part in the reverse ...
Basic inspection
WIRING SYSTEM > Basic Diagnostic ProcedureBASIC INSPECTION1. VOLTAGE MEASUREMENT1. Using a voltmeter, connect the negative lead to a good ground point or negative battery terminal and the positive lead to the connector or component terminal.2. Contact the positive lead of the voltmeter on connect ...