CONTROL SYSTEMS > General Diagnostic Table
INSPECTION
Symptoms | Possible cause | Corrective action |
Select lever | Starter does not run. | Adjust the select cable and inhibitor switch, or inspect the circuit. |
Back-up light does not illuminate. | Adjust the select cable and inhibitor switch, or inspect the circuit. | |
AT shift lock system does not operate normally. | Adjust the select cable and inhibitor switch, or inspect the circuit. | |
Manual mode can not be set. | Inspect the mode switch and select lever, or inspect the circuit. | |
Up-shift is not engaged at manual mode. | Check the shift-up switch and circuit. | |
Down-shift is not engaged at manual mode. | Check the shift-down switch and circuit. |
Body integrated unit Note
Cooling(h4do)Removal
LIGHTING SYSTEM > Combination Switch (Light)REMOVALCAUTION:Before handling the airbag system components, refer to “CAUTION” of “General Description” in “AIRBAG SYSTEM”. General Description > CAUTION">1. Set the tire to the straight-ahead position.2. ...
OFF delay timer
The following lights have an automatic
illumination function.
dome light
map light (type A)
cargo area light
After being illuminated automatically,
these lights remain on for several seconds
and then gradually turn off under the
following conditions
after all doors are closed (type A ...
Specification
MANUAL TRANSMISSION AND DIFFERENTIAL(5MT) > General DescriptionSPECIFICATION1. MANUAL TRANSMISSION AND DIFFERENTIALModelCrosstrek modelType5-forward speeds and 1-reverse (all stage with synchromesh)Transmission gear ratio1st3.5452nd1.8883rd1.2964th0.9725th0.780Rev.3.333Front reduction gearFinalTy ...