STEPCHECKYESNO

1.CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR.

1) Turn the ignition switch to ON.

2) Measure the voltage between ECM connector and chassis ground.

Connector & terminal

(B135) No. 18 (+) — Chassis ground (−):

Is the voltage 10 V or more?

Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2401 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT LOW">Go to Step 2.

Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2401 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT LOW">Go to Step 3.

2.CHECK FOR POOR CONTACT.

Check for poor contact of ECM connector.

Is there poor contact of ECM connector?

Repair the poor contact of ECM connector.

Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

NOTE:

In this case, temporary open or short circuit of harness or temporary poor contact of connector may be the cause.

3.CHECK POWER SUPPLY TO LEAK CHECK VALVE ASSEMBLY.

Measure the voltage between the leak check valve assembly connector and engine ground.

Connector & terminal

(R400) No. 3 (+) — Engine ground (−):

Is the voltage 10 V or more?

Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2401 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT LOW">Go to Step 4.

Repair the power supply circuit.

4.CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR.

1) Turn the ignition switch to OFF.

2) Disconnect the connector from ECM.

3) Disconnect the connector from the leak check valve assembly.

4) Measure the resistance between leak check valve assembly and chassis ground.

Connector & terminal

(R400) No. 4 — Chassis ground:

Is the resistance 1 M? or more?

Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2401 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT LOW">Go to Step 5.

Repair the short circuit to ground in harness between ECM connector and leak check valve assembly connector.

5.CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY CONNECTOR.

Measure the resistance of harness between ECM connector and the leak check valve assembly connector.

Connector & terminal

(B135) No. 18 — (R400) No. 4:

Is the resistance less than 1 ??

Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2401 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT LOW">Go to Step 6.

Repair the harness and connector.

NOTE:

In this case, repair the following item:

Open circuit in harness between ECM connector and the leak check valve assembly connector

Poor contact of coupling connector

6.CHECK LEAK CHECK VALVE ASSEMBLY.

Check the vacuum pump of the leak check valve assembly. Leak Check Valve Assembly > INSPECTION">

Is the check result OK?

Repair the poor contact in the leak check valve assembly connector.

Replace the leak check valve assembly. Leak Check Valve Assembly">

1. OUTLINE OF DIAGNOSIS

Detect the open or short circuit in Evaporative Leak Check Module vacuum pump.

Judge as NG if out of specification.

2. COMPONENT DESCRIPTION

(1)

Leak check valve ASSY

(5)

Vacuum pump

(9)

Fuel tank

(2)

Switching valve

(6)

Drain filter

(10)

Canister

(3)

Reference orifice (0.02 inch orifice)

(7)

Purge control solenoid valve

(4)

Pressure sensor

(8)

Intake manifold

3. EXECUTION CONDITION

Secondary Parameters

Execution condition

Battery voltage

≥ 10.9

Evaporative emission system leak detection pump command

= OFF

4. GENERAL DRIVING CYCLE

Always perform the diagnosis continuously.

5. DIAGNOSTIC METHOD

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Judgment Value

Malfunction Criteria

Threshold Value

Measured EVAP system leak detection pump voltage

≤ 12 V battery system voltage ? 0.34 V

Time Needed for Diagnosis: 2500 ms

Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.

Dtc p2271 o2 sensor signal biased/stuck rich bank 1 sensor 2
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P2271 O2 SENSOR SIGNAL BIASED/STUCK RICH BANK 1 SENSOR 2DTC detecting condition:Detected when two consecutive ...

Dtc p2402 evap system leak detection pump control circuit high
ENGINE (DIAGNOSTICS)(H4DO) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC P2402 EVAP SYSTEM LEAK DETECTION PUMP CONTROL CIRCUIT HIGHDTC detecting condition:Immediately at fault recogn ...

Other materials:

Preparation tool
GLASS/WINDOWS/MIRRORS > General DescriptionPREPARATION TOOL1. SPECIAL TOOLILLUSTRATIONTOOL NUMBERDESCRIPTIONREMARKS — SUBARU SELECT MONITOR 4Used for setting of each function and troubleshooting for electrical system.NOTE:For detailed operation procedures of Subaru Select Monitor 4, refer to &l ...

Clear memory mode Operation
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Clear Memory ModeOPERATION1. On «Start» display, select «Diagnosis».2. On «Vehicle selection» display, input the vehicle information and select «Confirmed».3. On «Main Menu» display, select «Each System».4. On «Select System» displa ...

Inspection
MECHANICAL(H4DO) > Cylinder BlockINSPECTION1. CYLINDER BLOCK & PISTON1. Visually inspect to make sure that there are no cracks, scratches or other damage.2. Use liquid penetrant tester on the important sections to check for fissures.3. Check that there are no traces of gas leaking or water le ...

© 2016-2024 Copyright www.sucross.com