1. Perform the preparation steps according to "Preparation for maintenance settings"
2. Operate the " " or " " switch to select the "Clear All Settings" item. Then push the button.
3. The system will prompt a Yes/No dialogue ("No" is selected first). To clear all maintenance settings, select "Yes" by operating the " " switch.
4. Confirm the setting by pushing the button.
5. The system will notify you that the setting is complete.
Active test Operation
ENGINE (DIAGNOSTICS)(H4DO) > Active TestOPERATIONCAUTION:After executing the system operation check mode, execute the Clear Memory Mode. Clear Memory Mode > OPERATION">NOTE:• *: After replacing ECM, be sure to perform this procedure.• For detailed operation procedures, ref ...
Dtc b28aa stereo camera microcomputer 1
EyeSight (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B28AA STEREO CAMERA MICROCOMPUTER 1Detected when communication error occurs due to malfunction of microcomputer inside the stereo camera.DTC DETECTING CONDITION:Communication error occurs due to malfunction of mic ...
Dtc b1016 shift lock circuit
BODY CONTROL SYSTEM (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC B1016 SHIFT LOCK CIRCUITDTC detecting condition:Open or power supply-output short, GND-output short in shift lock circuit.Trouble symptom:Shift lock does not be released or remain locked.Wiring diagram: ...