Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Inspection

HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient Sensor

INSPECTION

1. Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.

2. Check the resistance between ambient sensor terminals.

CAUTION:

During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.

Preparation tool:

Circuit tester

Terminal No.

Inspection conditions

Standard

1 — 2

10°C

5.82 — 6.18 k?

15°C

4.58 — 4.87 k?

20°C

3.64 — 3.86 k?

25°C

2.91 — 3.09 k?

30°C

2.35 — 2.49 k?

35°C

1.9 — 2.02 k?

40°C

1.56 — 1.65 k?

45°C

1.28 — 1.36 k?

50°C

1.06 — 1.12 k?

55°C

0.88 — 0.93 k?

60°C

0.74 — 0.78 k?

3. Replace the ambient sensor if the inspection result is not within the standard value.

Ambient sensor
...

Removal
HVAC SYSTEM (HEATER, VENTILATOR AND A/C) > Ambient SensorREMOVAL1. Disconnect the ground cable from battery. Battery > REMOVAL">2. Remove the ambient sensor.(1) Disconnect the connector ...

Other materials:

List
EyeSight (DIAGNOSTICS) > Diagnostic Code(s) DisplayLIST• List of Diagnostic Trouble Code (DTC)DTCItemContents of diagnosisReferenceU0073CONTROL MODULE COMMUNICATION BUS OFFDetected when bus off status (the stereo camera detects the failure and is disconnected from CAN line) occurs. Diagnost ...

Basic operation
By operating "  " or "  " of the control switch, the screens and selection items can be switched. When the " /SET" switch is pulled toward you, the item can be selected and set. If there are some useful messages, such as vehicle information, warning information, etc., they wi ...

Engine oil
CAUTION If the level gauge cannot be pulled out easily, twist the level gauge right and left, then gently pull it out. Otherwise, you may be injured accidentally straining yourself. Use only engine oil with the recommended grade and viscosity. Be careful not to spill engine oil ...

© 2016-2024 Copyright www.sucross.com