Subaru Crosstrek manuals

Subaru Crosstrek Service Manual: Dtc u0423 invalid data received from instrument panel cluster control module

CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)

DTC U0423 INVALID DATA RECEIVED FROM INSTRUMENT PANEL CLUSTER CONTROL MODULE

NOTE:

Refer to “LAN SYSTEM (DIAGNOSTICS)” for diagnostic procedures. Basic Diagnostic Procedure">

1. OUTLINE OF DIAGNOSIS

Detect malfunction of CAN communication.

Judge as NG when data received from the combination meter is not normal.

2. EXECUTION CONDITION

Secondary parameters

Execution condition

12 V battery system voltage

≥ 10 V

Measured turbine shaft speed

> 0 rpm

or

Transmission range

Drive or Reverse

3. DIAGNOSTIC METHOD

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Judgment Value

Malfunction Criteria

Threshold Value

CAN data from combination meter

Freeze

Time Needed for Diagnosis: 2 seconds

Malfunction Indicator Light Illumination: Does not illuminate.

Dtc u0422 invalid data received from body control module
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U0422 INVALID DATA RECEIVED FROM BODY CONTROL MODULENOTE:Refer to “LAN SYSTEM (DI ...

Dtc u0424 invalid data received from hvac control module
CONTINUOUSLY VARIABLE TRANSMISSION (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U0424 INVALID DATA RECEIVED FROM HVAC CONTROL MODULENOTE:Refer to “LAN SYSTEM (DI ...

Other materials:

Precautions in trouble diagnosis and repair of electric parts
WIRING SYSTEM > Working PrecautionsPRECAUTIONS IN TROUBLE DIAGNOSIS AND REPAIR OF ELECTRIC PARTS1. The battery cable must be disconnected from the battery’s (−) terminal, and the ignition switch must be set to the OFF position, unless otherwise required by the diagnostics.2. Securely ...

Inspection
FUEL INJECTION (FUEL SYSTEMS)(H4DO) > Rear Oxygen SensorINSPECTION1. Check that the rear oxygen sensor has no deformation, cracks or other damages.2. Measure the resistance between rear oxygen sensor terminals.Terminal No.Standard1 and 25.6+1.7 −0.6 ? (when 20°C (68°F) ...

Dtc u1650 invalid data received from meter (uart)
INSTRUMENTATION/DRIVER INFO (DIAGNOSTICS) > Diagnostic Procedure with Diagnostic Trouble Code (DTC)DTC U1650 INVALID DATA RECEIVED FROM METER (UART)DTC DETECTING CONDITION:There is an abnormality in UART data from combination meter.TROUBLE SYMPTOM:LCD is not displayed.WIRING DIAGRAM:Clearance Lig ...

© 2016-2021 Copyright www.sucross.com